NMWR-9-2815-220 Overhaul Manual for M60 M88 Engine AVDS-1790-2CA, AVDS-1790-2DA, AVDS-1790-2DR Download

Page 723 of 1014

NMWR 9-2815-220 GENERATOR AIR DUCTING OVERHAUL—Continued 0038 00 Table 2. Overhaul Inspection Procedure for Generator Air Exhaust Pipe (OIP 10935471) (Item3 , Figure 1). QA NO. REF. CHARACTERISTIC INSP. REQUISITE REQ. LTR. METHOD 1 Cracks Visual None allowed 2 Dented or deformed Visual None allowed tube ends 3 Fractured or missing Visual None allowed welds 0038 00-5