NMWR-9-2815-220 Overhaul Manual for M60 M88 Engine AVDS-1790-2CA, AVDS-1790-2DA, AVDS-1790-2DR Download
Page 682 of 1014
NMWR 9-2815-220 SMOKE GENERATING SYSTEM OVERHAUL—Continued 0034 00 CLEANING 1. Refer to WP 0005 00 for general cleaning instructions. CAUTION The valves contain rubber parts and should not be immersed in solvent. 2. Solenoid Valves. Plug inlet and outlet openings to prevent entrance of foreign material. Clean solenoid valves with a wiping rag moistened with cleaning compound solvent. INSPECTION 1. Inspect components not covered by an OIP in accordance with WP 0005 00. 2. Refer to WP 0005 00 and the OIPs in Table 1 for specific inspection criteria for selected items. 3. Discard all mandatory replacement parts. Refer to Figure 1. Table 1. Components Requiring Overhaul Inspection. COMPONENT OIP Fuel shut-off valve angle bracket (item 2, Figure 1) 12275809 (Table 2) Solenoid bracket (item 16, Figure 1) 12275712 (Table 4) Solenoid bracket (item 34, Figure 1) 12468924* and 12468927** (Table 6) *Models AVDS-1790-2CA and AVDS-1790-2DA **Model AVDS-1790-2DR REPAIR 1. Refer to WP 0005 00 for general repair instructions. ASSEMBLY 1. Refer to WP 0005 00 for general assembly procedures. 2. Assemble smoke generating system in accordance with TM 9-2815-220-34. 0034 00-2