West Coast Telecom Inc
CAGE Code: 4ZAL9
NCAGE Code: 4ZAL9
Status: Active
Type: Commercial Supplier
Dun & Bradstreet (DUNS): 809149219
Summary
West Coast Telecom Inc is an Active Commercial Supplier with the Cage Code 4ZAL9 and is tracked by Dun & Bradstreet under DUNS Number 809149219..
Address
5141 Azusa Canyon Rd
Baldwin Park CA 91706-1833
United States
Points of Contact
No Points of Contact...
Related Information
People who viewed this 'CAGE Code' also viewed...
Galloway G W Co Cititronics Inc Alan Wire Occo Enterprise Inc Camfel Productions Inc Carpet Pros Lumax Lighting Systems Inc Irwindale Cryogenics Corp Daley Business Forms Scan Tech Integrated Graphic Media Baldwin Park Congregate Home Inc Lawrence W. Rosine Co U S Bearings Barr Films Asari Plastic Corp Ads Intl Inc Littrell Sales Inc Mikhail Darafeen Inc Lawrence Roll Up Doors, Inc.
Frequently Asked Questions (FAQ) for CAGE 4ZAL9
- What is CAGE Code 4ZAL9?
- 4ZAL9 is the unique identifier used by NATO Organizations to reference the physical entity known as West Coast Telecom Inc located at 5141 Azusa Canyon Rd, Baldwin Park CA 91706-1833, United States.
- Who is CAGE Code 4ZAL9?
- 4ZAL9 refers to West Coast Telecom Inc located at 5141 Azusa Canyon Rd, Baldwin Park CA 91706-1833, United States.
- Where is CAGE Code 4ZAL9 Located?
- CAGE Code 4ZAL9 is located in Baldwin Park, CA, USA.
Contracting History for CAGE 4ZAL9 Most Recent 25 Records
- 47PK1818P0036
- Provide Supervision, Labor, And Material To Accomplish The Following At Fpd's West Side Floor Install One 2" Emt Conduit With 2" Strut Clamps. Install Deep Unistrut For 2" Conduit Support. Install One 24" Enclosed Wall Mount Cabinet. Install One New Om3 50 Micron 6 Strand Fiber Optic Cable From Server Room To West Side Cabinet. Install One 1U Corning Fiber Housing In Enclosed Wall Cabinet. Install One 6-Port Lc Fiber Panel In Fiber Housing. Terminate 6-Strand 50 Micron Fiber Onto 6 Lc Fiber Connectors. Install One New Cat6 Leviton 24 Port Patch Panel For West (A) Data Line Terminations. Install One New Cat6 Leviton 24 Port Patch Panel For West (B) Data Line Terminations. Install 22 Panel Cables Into West (A) Patch Panel. Install 22 Panel Cables Into West (B) Patch Panel. Install 22 White 3-Port Leviton White Face Plates For West Ports. Install 66 Cat6 Blue Leviton Connectors For West Locations. Install 3" Patch Cables From Patch Panel To West Side Network Switch, Switch Supplied By Fpd. East Side Floor Install One 2" Emt Conduit With 2" Strut Clamps. Install Deep Unistrut For 2" Conduit Support. Install One 24" Enclosed Wall Mount Cabinet. Install One New Om3 50 Micron 6-Strand Fiber Optic Cable From Server Room To East Side Cabinet. Install One 1U Corning Fiber Housing In 24" Enclosed Wall Cabinet. Install One 6-Port Lc Fiber Panel In Fiber Housing. Terminate 6-Strand 50 Micron Fiber Onto 6 Lc Fiber Connectors. Install One New Cat6 Leviton 24 Port Patch Panel For East (A) Data Line Terminations. Install One New Cat6 Leviton 24 Port Patch Panel For East (B) Data Line Terminations. Install 19 Panel Cables Into East (A) Patch Panel. Install 19 Panel Cables Into East (B) Patch Panel. Install 19 White 3-Port Leviton White Face Plates For East Ports. Install 57 Cat6 Blue Leviton Connectors For East Locations. Install 3" Patch Cables From Patch Panel To East Side Network Switch, Switch Supplied By Fpd. Mdf Server Room Install One 1U Corning Fiber Housing In Existing Relay Rack. Install Two 6 Port Lc Fiber Panels In Fiber Housing. Install One Black Blank In Fiber Housing. Specific Requirements: Remove Any Abandoned Structured Cabling Per Local And State Codes. All New Cat6 Cabling Installed To Be Certified Upon Completion Of Work. Follow Nec Standard Practice Codes. Provide Submittals Of All Material Being Installed For Agency Approval. The Contractor Shall Follow All Manufacturers Instructions And/Or Accepted Trade Practices, Whichever Is More Stringent. The Contractor Shall Take All The Necessary Precautions To Protect Surrounding Areas And Government Property From Damage. The Contractor Is Responsible For The Clean Up And Removal Of Any Debris Created During The Performance Of Work. Contractor To Verify All Site Conditions. No Allowances Will Be Made To Contractor For Failing To Familiarize Himself With All Of The Requirements As Described In This Specification.
- 10 Sep 2018
- Provide Supervision, Labor, And Material To Accomplish The Following At Fpd's West Side Floor Install One 2" Emt Conduit With 2" Strut Clamps. Install Deep Unistrut For 2" Conduit Support. Install One 24" Enclosed Wall Mount Cabinet. Install One New Om3 50 Micron 6 Strand Fiber Optic Cable From Server Room To West Side Cabinet. Install One 1U Corning Fiber Housing In Enclosed Wall Cabinet. Install One 6-Port Lc Fiber Panel In Fiber Housing. Terminate 6-Strand 50 Micron Fiber Onto 6 Lc Fiber Connectors. Install One New Cat6 Leviton 24 Port Patch Panel For West (A) Data Line Terminations. Install One New Cat6 Leviton 24 Port Patch Panel For West (B) Data Line Terminations. Install 22 Panel Cables Into West (A) Patch Panel. Install 22 Panel Cables Into West (B) Patch Panel. Install 22 White 3-Port Leviton White Face Plates For West Ports. Install 66 Cat6 Blue Leviton Connectors For West Locations. Install 3" Patch Cables From Patch Panel To West Side Network Switch, Switch Supplied By Fpd. East Side Floor Install One 2" Emt Conduit With 2" Strut Clamps. Install Deep Unistrut For 2" Conduit Support. Install One 24" Enclosed Wall Mount Cabinet. Install One New Om3 50 Micron 6-Strand Fiber Optic Cable From Server Room To East Side Cabinet. Install One 1U Corning Fiber Housing In 24" Enclosed Wall Cabinet. Install One 6-Port Lc Fiber Panel In Fiber Housing. Terminate 6-Strand 50 Micron Fiber Onto 6 Lc Fiber Connectors. Install One New Cat6 Leviton 24 Port Patch Panel For East (A) Data Line Terminations. Install One New Cat6 Leviton 24 Port Patch Panel For East (B) Data Line Terminations. Install 19 Panel Cables Into East (A) Patch Panel. Install 19 Panel Cables Into East (B) Patch Panel. Install 19 White 3-Port Leviton White Face Plates For East Ports. Install 57 Cat6 Blue Leviton Connectors For East Locations. Install 3" Patch Cables From Patch Panel To East Side Network Switch, Switch Supplied By Fpd. Mdf Server Room Install One 1U Corning Fiber Housing In Existing Relay Rack. Install Two 6 Port Lc Fiber Panels In Fiber Housing. Install One Black Blank In Fiber Housing. Specific Requirements: Remove Any Abandoned Structured Cabling Per Local And State Codes. All New Cat6 Cabling Installed To Be Certified Upon Completion Of Work. Follow Nec Standard Practice Codes. Provide Submittals Of All Material Being Installed For Agency Approval. The Contractor Shall Follow All Manufacturers Instructions And/Or Accepted Trade Practices, Whichever Is More Stringent. The Contractor Shall Take All The Necessary Precautions To Protect Surrounding Areas And Government Property From Damage. The Contractor Is Responsible For The Clean Up And Removal Of Any Debris Created During The Performance Of Work. Contractor To Verify All Site Conditions. No Allowances Will Be Made To Contractor For Failing To Familiarize Himself With All Of The Requirements As Described In This Specification.
- Pbs R9
- General Services Administration (Gsa)
- $31,637.48
- General Services Administration (Gsa)